RFC 2544
70 AXS-200/850
Back-to-Back Configuration
³ Verdict Threshold: Set the threshold value in percentage of frames per
burst for the test. If the determined back-to-back value is greater or
equal to the threshold value, the test is declared as PASS. If the
determined back-to-back value for a specific frame size is lower than
the threshold value, the test is declared as FAIL. This value should
range from 0.1% to 100% and applies to all the 7 RFC 2544 frame sizes
or for the 7 user-defined frame sizes.
Note: When the Dual Test Set parameter is
set to Local in Global Configuration
on page 58, the Verdict Threshold is
configured independently for each
direction: Local-to-Remote and
Remote-to-Local.