Preparing RFC 2544 for Analysis
10 Gigabit Ethernet Analyzer 35
Setting Test Parameters
Parameters of the Frame Loss Rate Test
The Start rate (L1) and Stop rate (L1) fields allow setting the range of load
values to be used for performing the loss rate analysis. Raw data rate
values (L1) can be specified in percentage terms ( ), Kbps ( ) or
Mbps ( ).
Enabled Enabling/disabling the deviation loss rate analysis.
Trial, s The period of time during which the test should be per-
formed for each frame size specified in the settings
(1-3600 s).
Steps qty The number of load adjustment steps.