Exfo FTB-7000 OTDR for FTB-200 v2 Manuel d'utilisateur Page 133

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 339
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 132
Analyzing Traces and Events
OTDR 119
Selecting the Default View
Selecting the Default View
You can select which view will be displayed by default once all the
acquisitions are performed (at all the selected wavelengths) and the
analysis of the last wavelength is complete.
The table below indicates in which OTDR modes (Auto, Advanced,
Template) a particular view can be displayed.
View
OTDR modes
for which view
is available
Remarks
Graph ³ Auto
³ Advanced
³ Template
Default view.
For more information, see Graph
View on page 106
Linear
³ Auto
³ Advanced
³ Template
Available with the optional software
package only.
In this view, events are displayed
sequentially, from left to right.
Macrobends are identified with
symbols on the trace corresponding
to the greatest wavelength of the
pair of wavelengths.
For more information, see Linear
View on page 108.
Vue de la page 132
1 2 ... 128 129 130 131 132 133 134 135 136 137 138 ... 338 339

Commentaires sur ces manuels

Pas de commentaire