Exfo BV10 Performance Endpoint Unit Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Exfo BV10 Performance Endpoint Unit. EXFO BV10 Performance Endpoint Unit User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 116
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - Performance Endpoint Unit

User GuidePerformance Endpoint UnitBV10

Page 3 - Certification Information

Specifications94 BV10General SpecificationsAC/DC AdapterTe m p er at ur eOperating:Storing:–10 °C to 50 °C (14 °F to 122 °F) –20 °C to 85 °C (–4 °F to

Page 4 - Contents

SpecificationsBV10-100 and BV10-1000 95Electrical InterfaceElectrical Interface Optical Interface Electrical interface One 10/100/1000 Base-T portTx b

Page 6

BV10-100 and BV10-1000 97B Glossary Acronym List ABCD?HelpA Ampere AC Alternating CurrentACT ActivityARP Address Resolution ProtocolAWG American Wir

Page 7 - 1 Introducing the BV10

Glossary98 BV10Acronym ListEFGICDA Clean Dry Air DHCP Dynamic Host Configuration Protocol DMM Delay Measurement Message ESD Electrostatic Discharge E

Page 8 - BrixWorx for Turn Up

GlossaryBV10-100 and BV10-1000 99Acronym ListKLMNkg Kilogram LAN Local Area NetworkLBM Loopback MessageLC Lucent Connector LED Light-Emitting Diodelb

Page 9

Glossary100 BV10Acronym ListOPRSTOAM Operation, Administration, and MaintenanceOUT OUTputPC Personal ComputerRMA Return Merchandise Authorizationrtt

Page 10

GlossaryBV10-100 and BV10-1000 101Acronym ListUVUDP User Data ProtocolUSA United States of America UTP Unshielded Twisted Pairs VVolt VLAN Virtual L

Page 11 - 2 Safety Information

Glossary102 BV10Ethernet CablesEthernet Cables Minimum Category 3 cable is required for 10Base-T connection while Category 5 cable is required for 100

Page 12

GlossaryBV10-100 and BV10-1000 103Ethernet Cables Straight Through Cable (1000 Mbit/s) Crossover Cable (1000 Mbit/s)

Page 13 - IMPORTANT

BV10-100 and BV10-1000 52 Safety Information WARNINGDo not install or terminate fibers while a light source is active. Never look directly into a live

Page 15 - 3 Getting Started

IndexBV10-100 and BV10-1000 105IndexAAC/DC power connection ... 12Acronym...

Page 16 - Connecting the Power

Index106 BV10FFC connector cleaner... 84Features ... 1front panel

Page 17 - Grounding the BV10

IndexBV10-100 and BV10-1000 107Wwarrantycertification ... 89exclusions ...

Page 18

NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Page 19

MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( ㄃ )Logo㪖㉦This E;)2 product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl

Page 20

www.EXFO.com · [email protected]/N: 1067241CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-

Page 21 - BV10 Models

Safety Information6 BV10Additional Laser Safety InformationAdditional Laser Safety Information WARNINGThis product employs Class 1 Laser SFP. Invisibl

Page 22 - Port Availability on BV10

Safety InformationBV10-100 and BV10-1000 7Installation Instruction WarningsInstallation Instruction WarningsCAUTIONNo user serviceable parts are conta

Page 23 - SFP Port (BV10-1000)

Safety Information8 BV10Other Safety Symbols on Your UnitOther Safety Symbols on Your Unit One or more of the following symbols may also appear on you

Page 24 - LAN Port

BV10-100 and BV10-1000 93 Getting Started Installing the BV10 in a Rack The BV10 can be mounted in a rack using the rack mount accessory kit (ordered

Page 25 - CONSOLE Port

Getting Started10 BV10Connecting the PowerConnecting the Power The BV10 is available with either an AC power supply, DC +24 V connector, or DC –48 V c

Page 26

Getting StartedBV10-100 and BV10-1000 11Connecting the PowerGrounding the BV10The BV10 is equipped with a ground lug and hardware attached to the back

Page 27 - RESET and DEFAULT Buttons

Getting Started12 BV10Connecting the PowerConnecting the BV10 using an AC/DC Power SourceThe typical output voltage of the external brick AC power sup

Page 28

Getting StartedBV10-100 and BV10-1000 13Connecting the PowerThe following figures show the –48 V and +24 V DC units.--2. Connect the plug to one of th

Page 29 - BrixWorx

ii BV10Copyright © 2010–2014 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted

Page 30 - Configuring a Test

Getting Started14 BV10Connecting the Power3. Connect the other end of the wires to the DC power source.4. To add a redundant DC power source on the BV

Page 31 - 2. Select Verifiers

BV10-100 and BV10-1000 154 Physical Interfaces, LEDs, and ButtonsThis section describes all connectors (ports), LEDs, and buttons available on the BV1

Page 32

Physical Interfaces, LEDs, and Buttons16 BV10Port Availability on BV10Port Availability on BV10 Connecting the TEST Port Interface The BV10-100 provid

Page 33

Physical Interfaces, LEDs, and ButtonsBV10-100 and BV10-1000 17Connecting the TEST Port InterfaceSFP Port (BV10-1000)The BV10-1000 provides an optiona

Page 34 - Verifier Health Information

Physical Interfaces, LEDs, and Buttons18 BV10Connecting the Management InterfacesConnecting the Management InterfacesThe management interface can be c

Page 35 - 6 Introducing the BV10 CLI

Physical Interfaces, LEDs, and ButtonsBV10-100 and BV10-1000 19Connecting the Management InterfacesCONSOLE PortConnecting a PC to the CONSOLE port pro

Page 36

Physical Interfaces, LEDs, and Buttons20 BV10LEDsLEDs POWER  On (Green) indicates that the BV10 unit is receiving power from an external source. Off

Page 37

Physical Interfaces, LEDs, and ButtonsBV10-100 and BV10-1000 21RESET and DEFAULT ButtonsRESET and DEFAULT Buttons The RESET and DEFAULT buttons are re

Page 39 - Entering Commands

BV10-100 and BV10-1000 235 Managing BV10 Verifier on BrixWorx This chapter describes how to configure and use BV10 hardware on BrixWorx. It explains t

Page 40 - Completing Commands

Certification InformationBV10-100 and BV10-1000 iiiCertification InformationNorth America Regulatory StatementThis unit was certified by an agency app

Page 41 - Command Editing Keys

Managing BV10 Verifier on BrixWorx24 BV10Configuring a Test3. To configure the port of communication, type the following command:BV10-1000 (DEBUG)>

Page 42 - Command History

Managing BV10 Verifier on BrixWorxBV10-100 and BV10-1000 25Configuring a TestTo configure a test on a BV10 Verifier using the BrixWorx Operations Cent

Page 43 - CLI Session

Managing BV10 Verifier on BrixWorx26 BV10Configuring a Test3. Click the name of the Verifier on which you want to configure the test.4. Click the edit

Page 44

Managing BV10 Verifier on BrixWorxBV10-100 and BV10-1000 27Configuring a Test5. Enter the time interval at which you want the BV10 Verifier to report

Page 45 - 7 CLI Command Reference

Managing BV10 Verifier on BrixWorx28 BV10Verifier Health InformationVerifier Health InformationThe BV10 Verifier runs its health status test based on

Page 46 - Command Page

BV10-100 and BV10-1000 296 Introducing the BV10 CLI This chapter describes the BV10 Ethernet Performance Endpoints Command Line Interface (CLI), its u

Page 47

Introducing the BV10 CLI30 BV10Connecting to the BV10 to a ConsoleConnecting to the BV10 to a Console Connect the BV10 to a Console for management thr

Page 48 - Operation Commands

Introducing the BV10 CLIBV10-100 and BV10-1000 31Connecting to the BV10 to a ConsoleLAN Port A console it connected to the BV10 (LAN port) for remote

Page 49 - Help Commands

Introducing the BV10 CLI32 BV10Connecting to the BV10 to a ConsoleTEST Port In-band management activities on the TEST port is provided for basic confi

Page 50

Introducing the BV10 CLIBV10-100 and BV10-1000 33Entering CommandsEntering CommandsOnce you have connected to the BV10, you can enter CLI commands at

Page 51 - System Commands

iv BV10ContentsCertification Information ... iii1

Page 52 - Software Management Commands

Introducing the BV10 CLI34 BV10Entering CommandsCompleting CommandsTo submit a CLI command, press the Enter key. The CLI command completion feature le

Page 53

Introducing the BV10 CLIBV10-100 and BV10-1000 35Entering CommandsCommand Editing KeysThe CLI uses common line editing key sequences, as shown in the

Page 54 - CLI Command Reference

Introducing the BV10 CLI36 BV10Entering CommandsNote: Not all key sequences are available to the SSH client. Because an SSH client buffers data before

Page 55 - Statistics Commands

Introducing the BV10 CLIBV10-100 and BV10-1000 37CLI SessionCLI SessionAll commands are available at any time once a communication session has been es

Page 57 - Interface Information Command

BV10-100 and BV10-1000 397 CLI Command Reference This chapter describes the BV10 command line interface (CLI). The commands are grouped under Operatio

Page 58

CLI Command Reference40 BV10Alphabetical List of CLI CommandsAlphabetical List of CLI Commands The following table lists the BV10 CLI commands in alph

Page 59 - Tools Command

CLI Command ReferenceBV10-100 and BV10-1000 41Alphabetical List of CLI Commandsinterface test vlan priority value 67load image 47logout or exit 45pass

Page 60 - Server Discovery Commands

CLI Command Reference42 BV10Operation CommandsOperation Commands Operation commands allow to view and change the operational behavior of the BV10. Ope

Page 61

CLI Command ReferenceBV10-100 and BV10-1000 43Operation CommandsHelp Commandshelp Description Displays a list of top-level CLI commands with a descrip

Page 62

BV10-100 and BV10-1000 v8 Test Applications ... 73Smart Loopback

Page 63

CLI Command Reference44 BV10Operation Commands? Description Displays context-sensitive help. You can enter the ? alone at the CLI prompt, at the end o

Page 64 - Configuration Commands

CLI Command ReferenceBV10-100 and BV10-1000 45Operation CommandsSystem Commandsreboot Description Restarts the BV10. Before restarting the unit, the C

Page 65 - General Command

CLI Command Reference46 BV10Operation CommandsSoftware Management Commandsshow sysinfo Description Displays the following BV10 unit information: Soft

Page 66

CLI Command ReferenceBV10-100 and BV10-1000 47Operation Commandsload image Description Loads a software upgrade/downgrade image from TFTP or FTP (usin

Page 67 - Console Commands

CLI Command Reference48 BV10Operation CommandsSyntaxload image lan|test uri The URI can use one of the following formats, depending on the server type

Page 68

CLI Command ReferenceBV10-100 and BV10-1000 49Operation CommandsStatistics Commandsshow statistics Description Displays the following status and stati

Page 69

CLI Command Reference50 BV10Operation Commandsclear statistics Description Clears the counter of all statistics.Syntaxclear statisticsExamplebv10-100&

Page 70

CLI Command ReferenceBV10-100 and BV10-1000 51Operation CommandsInterface Information Commandshow interface Description Displays information about the

Page 71

CLI Command Reference52 BV10Operation CommandsExamplebv10-100> show interface allLAN PORTIP_ADDRESS = 10.17.16.32NETMASK = 255.255.0.0MAC_ADDRESS =

Page 72

CLI Command ReferenceBV10-100 and BV10-1000 53Operation CommandsTools Commandping Description Initiates a ping of a specified destination using the LA

Page 74

CLI Command Reference54 BV10Operation CommandsServer Discovery Commands Note: The following commands are only effective when used in a BrixWorx enviro

Page 75

CLI Command ReferenceBV10-100 and BV10-1000 55Operation Commandsserver discovery port Description Sets the BrixWorx local registry port for communicat

Page 76 - Test Application Commands

CLI Command Reference56 BV10Operation Commandsshow server discovery local Description Displays the IP address of the currently set local BrixWorx regi

Page 77

CLI Command ReferenceBV10-100 and BV10-1000 57Operation Commandsshow server log Description Displays the server log for the local BrixWorx registry.Sy

Page 78

CLI Command Reference58 BV10Configuration CommandsConfiguration CommandsBV10 Configuration commands allow to view and change the configuration of the

Page 79 - 8 Test Applications

CLI Command ReferenceBV10-100 and BV10-1000 59Configuration CommandsGeneral Command Test Application smart-loopback enable|disablesmart-loopback mode

Page 80 - Smart Loopback Test

CLI Command Reference60 BV10Configuration CommandsExamplebv10-100> show configConsoleCONSOLE_IN_BAND = enabled CONSOLE_PASSWORD = disabledCONSOLE_T

Page 81 - Operational Status

CLI Command ReferenceBV10-100 and BV10-1000 61Configuration CommandsConsole Commandspassword set password Description Defines a password for the BV10.

Page 82 - Ping Test

CLI Command Reference62 BV10Configuration Commandsconsole in-band enable|disable Description Enables or disables in-band management on the Test port.

Page 83 - TWAMP Light Responder Test

CLI Command ReferenceBV10-100 and BV10-1000 63Configuration CommandsInterface Configuration CommandsThe following commands allow setting the port inte

Page 84 - UDP Echo Responder Test

BV10-100 and BV10-1000 11 Introducing the BV10 Highly cost-effective Ethernet performance monitoring device providing complete network visibility for

Page 85 - Ethernet OAM Handling Test

CLI Command Reference64 BV10Configuration Commandsinterface lan|test speed auto Description Auto-negotiates all supported LAN (10/100) or Test (10/100

Page 86

CLI Command ReferenceBV10-100 and BV10-1000 65Configuration Commandsinterface lan speed 10|100 force Description Forces the LAN port speed (10/100) to

Page 87 - 9 Power Failure Recovery

CLI Command Reference66 BV10Configuration Commandsinterface lan duplex half|full Description Sets the LAN duplex to either half or full; no auto-negot

Page 88

CLI Command ReferenceBV10-100 and BV10-1000 67Configuration Commandsinterface lan|test cable auto Description Automatically detects the LAN or electri

Page 89 - 10 Maintenance

CLI Command Reference68 BV10Configuration Commandsinterface lan|test address-netmask IP_address/netmask|dhcp Description Sets the IP address and subne

Page 90 - Recycling and Disposal

CLI Command ReferenceBV10-100 and BV10-1000 69Configuration Commandsinterface lan|test gateway dhcp|none Description When the LAN or TEST interface IP

Page 91 - 11 Troubleshooting

CLI Command Reference70 BV10Configuration CommandsTest Application Commandssmart-loopback enable|disable Description Enables or disables the Smart Loo

Page 92 - Transportation

CLI Command ReferenceBV10-100 and BV10-1000 71Configuration Commandstwamp enable|disable Description Enables or disables the TWAMP Light application.

Page 93 - 12 Warranty

CLI Command Reference72 BV10Configuration Commandseth-oam enable|disable Description Globally enables or disables the Ethernet OAM handling applicatio

Page 94 - Liability

BV10-100 and BV10-1000 738 Test Applications The BV10 supports the following test applications: Smart Loopback supports wire-speed operation with TWAM

Page 95

Introducing the BV102 BV10BrixWorx for Turn UpBrixWorx for Turn Up BrixWorx for Turn Up is a system designed for Turn-Up and reflector testing with no

Page 96 - Service and Repairs

Test Applications74 BV10Smart Loopback TestSmart Loopback Test The Smart Loopback feature loops back the stream of data (frames/packets). It retransmi

Page 97 - BV10-100 and BV10-1000 91

Test ApplicationsBV10-100 and BV10-1000 75Smart Loopback TestOperational Status The following table indicates the rules that determine the Smart Loopb

Page 98

Test Applications76 BV10Ping TestPing Test The Ping test (applicable to the LAN and Test ports) provides the ability to generate ICMP Echo Requests an

Page 99 - ASpecifications

Test ApplicationsBV10-100 and BV10-1000 77TWAMP Light Responder TestTWAMP Light Responder Test The TWAMP Light Responder test listens for TWAMP Light

Page 100 - AC/DC Adapter

Test Applications78 BV10UDP Echo Responder TestUDP Echo Responder Test The UDP Echo Responder test listens for UDP Echo messages and responds with a r

Page 101 - Optical Interface

Test ApplicationsBV10-100 and BV10-1000 79Ethernet OAM Handling TestEthernet OAM Handling Test The Ethernet OAM handling test listens for Ethernet OAM

Page 102

Test Applications80 BV10Ethernet OAM Handling Test Frame Delay (two-way)The BV10 supports two-way Frame Delay. The BV10 responds to Ethernet OAM Fram

Page 103 - B Glossary

BV10-100 and BV10-1000 819 Power Failure RecoveryIn the case of a power failure, the BV10 unit:  recovers automatically when power is restored.  ret

Page 105

BV10-100 and BV10-1000 8310 Maintenance To help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them and clea

Page 106 - 100 BV10

Introducing the BV10BV10-100 and BV10-1000 3ConventionsConventionsBefore using the product described in this guide, you should understand the followin

Page 107

Maintenance84 BV10Cleaning LC ConnectorsCleaning LC ConnectorsUnder normal circumstances the cleaning of the LC connector is not required. However if

Page 108 - Ethernet Cables

BV10-100 and BV10-1000 8511 Troubleshooting Solving Common Problems Before calling EXFO’s technical support, please read the following common problems

Page 109 - Crossover Cable (1000 Mbit/s)

Troubleshooting86 BV10Contacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or technical support f

Page 110

BV10-100 and BV10-1000 8712 Warranty General InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship for a per

Page 111 - BV10-100 and BV10-1000 105

Warranty88 BV10LiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any failure

Page 112

WarrantyBV10-100 and BV10-1000 89ExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its products at a

Page 113 - BV10-100 and BV10-1000 107

Warranty90 BV10Service and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the date of purchas

Page 114 - ₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩

WarrantyBV10-100 and BV10-1000 91EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact your nearest

Page 116

BV10-100 and BV10-1000 93ASpecifications General Specifications BV10Size (H x W x D) 38 mm x 103 mm x 210 mm (1 1/2 in x 4 1/16 in x 8 1/4 in) Weight