Exfo FTB-610 Wideband Copper Test Module Manuel d'utilisateur Page 360

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 364
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 359
Technische Daten
352 FTB-610
PM-1 BUILT-IN POWER METER SPECIFICATIONS
a
Calibrated wavelengths (nm) 850, 1300, 1310, 1490, 1550, 1625, 1650
Optional CWDM calibrated
wavelengths (nm)
1270, 1290, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490,
1510, 1530, 1550, 1570, 1590, 1610, 1383, 1625
Power range (dBm) 10 to —86 (InGaAs)
26 to —64 (GeX)
Uncertainty (%)
b
±5 % ± 3 pW (InGaAs)
±5 % ± 0.4 nW (GeX)
Display resolution (dB)
InGaAs
GeX
0.01 = max to —76 dBm
0.1 = —76 dBm to —86 dBm
1 = —86 dBm to min
0.01 = max to —54 dBm
0.1 = —50 dBm to —60 dBm
1 = —60 dBm to min
Automatic offset nulling range
c
Max power to —63 dBm for InGaAs
Max power to —40 dBm for GeX
Tone detection (Hz) 270/1000/2000
Notes
a. At 23 ºC ± 1 ºC, 1550 nm and FC connector. With modules in Idle mode. Battery-operated.
b. Up to 5 dBm.
c. For ±0.05 dB, from 18 ºC to 28 ºC.
Vue de la page 359
1 2 ... 355 356 357 358 359 360 361 362 363 364

Commentaires sur ces manuels

Pas de commentaire