Exfo PSO-200 Optical Modulation Analyzer Manuel d'utilisateur Page 152

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 285
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 151
SCPI Commands Reference
144 PSO-200
Product-Specific Commands—Description
:SENSe:DDEMod:AVERage:COUNt?
Description This query returns the number of bursts used to
calculate average results.
At *RST, this value is 0.
Syntax :SENSe:DDEMod:AVERage:COUNt?
Parameter(s) None
Response Syntax <Average Count>
Response(s) Average Count:
The response data syntax for <Average Count>
is defined as a <NR1 NUMERIC RESPONSE
DATA> element.
Returns the number of bursts used to calculate
average results.
Example(s) SENSe:DDEMod:AVERage:COUNt 20
SENSe:DDEMod:AVERage:COUNt? Returns 20
See Also SENSe:DDEMod:AVERage:TCONtrol?