Exfo iOLM Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Exfo iOLM. EXFO iOLM User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 186
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - User Guide

User Guideintelligent Optical Link MapperiOLM

Page 2

Introducing the intelligent Optical Link Mapper4 iOLMOTDR port (singlemode live)OTDR port (singlemode)Active LED(on when laser is emitting)MAX-700B Se

Page 4

intelligent Optical Link Mapper 959 Using the Inline Power Meter (Optional on Some Models)This section will help you use the inline power meter and pe

Page 5

Using the Inline Power Meter (Optional on Some Models)96 iOLMUnderstanding the Inline Power MeterA visual representation of the power value for each c

Page 6 - Certification Information

Using the Inline Power Meter (Optional on Some Models)intelligent Optical Link Mapper 97Performing a Power Meter AcquisitionPerforming a Power Meter A

Page 7 - Optical Link Mapper

Using the Inline Power Meter (Optional on Some Models)98 iOLMSaving the Power LevelWhen both wavelengths of a two-channels power meter are selected, b

Page 8

Using the Inline Power Meter (Optional on Some Models)intelligent Optical Link Mapper 99Saving the Power LevelThe saved power level is also displayed

Page 9 - Singlemode and

Using the Inline Power Meter (Optional on Some Models)100 iOLMiOLM Acquisition with Power MeteriOLM Acquisition with Power MeterThe iOLM and power met

Page 10 - MAX-700B Series

Using the Inline Power Meter (Optional on Some Models)intelligent Optical Link Mapper 101iOLM Acquisition with Power Meter3. Select the SM Live Port a

Page 12

intelligent Optical Link Mapper 10310 Using the OTDR as a Source (Optional on Some Models)The Source tab allows you to operate the existing OTDR laser

Page 13

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 5Principles of OperationPrinciples of OperationThe iOLM application use

Page 14

Using the OTDR as a Source (Optional on Some Models)104 iOLM2. Select the desired wavelength from the Wavelength list.

Page 15

Using the OTDR as a Source (Optional on Some Models)intelligent Optical Link Mapper 1053. Select the desired modulation from the Modulation list. Sele

Page 17

intelligent Optical Link Mapper 10711 Starting the OTDR ApplicationYou can start the classic OTDR application without leaving the iOLM application. Yo

Page 18

Starting the OTDR Application108 iOLM2. Tap Start to start the OTDR acquisition. For more information, refer to the OTDR user guide.Note: The aspect o

Page 19 - 2 Safety Information

intelligent Optical Link Mapper 10912 Managing ResultsThis section explains the link view, measurement information, element details, and the results d

Page 20

Managing Results110 iOLMLink ViewLink OverviewThe link overview shows the entire link without scrolling. You can directly select an element by tapping

Page 21 - Safety Information

Managing Resultsintelligent Optical Link Mapper 111Link ViewElements before A and after B are referred to as out of span elements. Elements out of the

Page 22

Managing Results112 iOLMLink View Letter B: The end of the link under test.Note: An arrow ( ) icon is displayed on the element, if the start and the

Page 23 - 3 Getting Started with Your

Managing Resultsintelligent Optical Link Mapper 113Link View Loop Start icon : Indicates the beginning of the loop. Loop End icon : Indicates the

Page 24 - Status Bar

Introducing the intelligent Optical Link Mapper6 iOLMPerforming Multimode MeasurementsPerforming Multimode MeasurementsIf your module supports multimo

Page 25

Managing Results114 iOLMLink ViewLink GroupsLink elements will be displayed as groups when the iOLM analysis detects several link elements that are to

Page 26

Managing Resultsintelligent Optical Link Mapper 115Link ViewEach sub-element is directly displayed as if they were normal elements. See Link Compositi

Page 27

Managing Results116 iOLMLink ViewLink View ElementsElement Name Element Icon Element DescriptionMacrobends Macrobends can be displayed in the link vie

Page 28

Managing Resultsintelligent Optical Link Mapper 117Link ViewiOLM ResultsThe iOLM acquisition results are displayed in the iOLM table for all the wavel

Page 29 - 5 Setting User Preferences

Managing Results118 iOLMLink ViewPower Meter ResultsThe power meter acquisition results are displayed in the OPM table for all the wavelengths at whic

Page 30 - Defining General Settings

Managing Resultsintelligent Optical Link Mapper 119Link ViewLoopback ResultsThe loopback measurement is especially designed for testing cables formed

Page 31

Managing Results120 iOLMLink ViewGlobal Pass/Fail StatusThe global pass/fail status depends on the pass/fail status of the link length, link loss, lin

Page 32

Managing Resultsintelligent Optical Link Mapper 121Viewing Element and Section DetailsViewing Element and Section DetailsWhen an element or section is

Page 33 - Numeric and alphanumeric

Managing Results122 iOLMViewing Element and Section Details2. From the main window, tap the Elements tab. You can view the selected element or section

Page 34 - Customizing the File Name

Managing Resultsintelligent Optical Link Mapper 123Viewing Element and Section Details In loopback mode, the application displays the link start (A),

Page 35 - 2. Select the Filename tab

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 7Launch, Receive, and Loop FiberLaunch, Receive, and Loop FiberUnlike a

Page 36

Managing Results124 iOLMViewing Element and Section DetailsNote: If the type of an element is modified, a “*” sign is displayed at the value in the Ty

Page 37

Managing Resultsintelligent Optical Link Mapper 125Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)Managing Elements a

Page 38

Managing Results126 iOLMManaging Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)To add an element:1. Open an iOLM file.2. Sele

Page 39 - Next file name

Managing Resultsintelligent Optical Link Mapper 127Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)4. In the New Eleme

Page 40

Managing Results128 iOLMManaging Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)The application also allows you to add an elem

Page 41

Managing Resultsintelligent Optical Link Mapper 129Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)4. Enter the positi

Page 42

Managing Results130 iOLMManaging Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)When you add a new element to an element or gr

Page 43 - Customizing the iOLM Report

Managing Resultsintelligent Optical Link Mapper 131Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)Deleting ElementsTh

Page 44

Managing Results132 iOLMManaging Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)4. Select Delete Element from the contextual m

Page 45

Managing Resultsintelligent Optical Link Mapper 133Managing Elements and Analyzing Links (Optional, iOLM EXpert and Loopback Modes)To analyze the link

Page 46

Introducing the intelligent Optical Link Mapper8 iOLMLaunch, Receive, and Loop Fiberreceive fiber has the same limitations than that of a traditional

Page 47

Managing Results134 iOLMMeasurement InformationMeasurement InformationYou can find information about a measurement, in the application, such as the fi

Page 48 - Configuring your iOLM

Managing Resultsintelligent Optical Link Mapper 135Measurement InformationTo view identification information:1. From the main window tap Measurement I

Page 49

Managing Results136 iOLMMeasurement InformationTo view measurement settings:1. From the main window, tap Measurement Info.2. Tap Settings.3. By defaul

Page 50

intelligent Optical Link Mapper 13713 Managing FilesThe File menu allows you to open an existing file, save a file, and generate a report from the mea

Page 51

Managing Files138 iOLMOpening iOLM Files2. Tap Open.3. Select the file you want to open and tap Open.Note: Depending on the type of unit you are using

Page 52 - 2. Tap Select

Managing Filesintelligent Optical Link Mapper 139Saving iOLM FilesSaving iOLM FilesThe Save or Save As menu item allows you to save an existing iOLM f

Page 53

Managing Files140 iOLMSaving iOLM Files2. Tap either Save to overwrite the existing file with the new file, or Save As to enter a new name or location

Page 54

Managing Filesintelligent Optical Link Mapper 141Saving iOLM Files3. Enter the file name and tap Save.Note: Depending on the type of unit you are usin

Page 55 - Creating a Test Configuration

Managing Files142 iOLMExporting OTDR Bellcore FilesExporting OTDR Bellcore FilesThe Export option allows you to manually export a OTDR Bellcore file t

Page 56 - 4. Tap Duplicate

Managing Filesintelligent Optical Link Mapper 143Exporting OTDR Bellcore Files2. Tap Export to save the file in .sor format.

Page 57

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 9Launch, Receive, and Loop FiberThe loopback measurement is designed to

Page 58 - Modifying Identifiers

Managing Files144 iOLMExporting OTDR Bellcore Files3. The default file name is displayed in the File name field. You can edit the file name and tap Sa

Page 59

Managing Filesintelligent Optical Link Mapper 145Generating a ReportGenerating a ReportThe Report menu item allows you to generate an iOLM report, Pow

Page 60 - Modifying Link Definition

Managing Files146 iOLMGenerating a ReportTo generate a report:1. From the Main Menu, tap File.2. Tap Report.

Page 61 - To modify link definition:

Managing Filesintelligent Optical Link Mapper 147Generating a Report3. Enter the report file name and tap Save.Note: Depending on the type of unit you

Page 63

intelligent Optical Link Mapper 14914 MaintenanceTo help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them

Page 64

Maintenance150 iOLMCleaning EUI ConnectorsTo clean EUI connectors:1. Remove the EUI from the instrument to expose the connector baseplate and ferrule.

Page 65 - Mode Only)

Maintenanceintelligent Optical Link Mapper 151Cleaning EUI Connectors6. Clean the ferrule in the connector port as follows:6a. Deposit one drop of iso

Page 66

Maintenance152 iOLMRecalibrating the UnitRecalibrating the UnitEXFO manufacturing and service center calibrations are based on the ISO/IEC 17025 stand

Page 67 - 5. Enable 2:N splitter

Maintenanceintelligent Optical Link Mapper 153Recycling and Disposal (Applies to European Union Only)To help you with calibration follow-up, EXFO prov

Page 68

Introducing the intelligent Optical Link Mapper10 iOLMSoftware OptionsSoftware OptionsSoftware options are offered with your unit. The iOLM software

Page 70

intelligent Optical Link Mapper 15515 TroubleshootingViewing Online DocumentationAn online version of the intelligent Optical Link Mapper user guide i

Page 71

Troubleshooting156 iOLMContacting the Technical Support GroupContacting the Technical Support GroupTo obtain after-sales service or technical support

Page 72

Troubleshootingintelligent Optical Link Mapper 157Viewing Information About the ProductViewing Information About the ProductYou can view the product v

Page 73

Troubleshooting158 iOLMTransportationTransportationMaintain a temperature range within specifications when transporting the unit. Transportation damag

Page 74

intelligent Optical Link Mapper 15916 WarrantyGeneral InformationEXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship

Page 75

Warranty160 iOLMLiabilityLiabilityEXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any failure

Page 76 - 4. Tap Modify

Warrantyintelligent Optical Link Mapper 161ExclusionsExclusionsEXFO reserves the right to make changes in the design or construction of any of its pro

Page 77

Warranty162 iOLMService and RepairsService and RepairsEXFO commits to providing product service and repair for five years following the date of purcha

Page 78

Warrantyintelligent Optical Link Mapper 163EXFO Service Centers WorldwideEXFO Service Centers WorldwideIf your product requires servicing, contact you

Page 79

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 11ConventionsConventionsBefore using the product described in this guid

Page 81

intelligent Optical Link Mapper 165A Technical SpecificationsFTB-720IMPORTANTThe following technical specifications can change without notice. The inf

Page 82

Technical Specifications166 iOLMFTB-720GFTB-720GNote: The following specifications are for the OTDR instrument. Refer to the Transport Application use

Page 83

Technical Specificationsintelligent Optical Link Mapper 167FTB-730FTB-730TECHNICAL SPECIFICATIONS (OTDR)Model FTB-730 aWavelength (nm) b1310 ± 20/1490

Page 84

Technical Specifications168 iOLMFTB-730GFTB-730GNote: The following specifications are for the OTDR instrument. Refer to the Transport Application use

Page 85 - Deleting Test Configuration

Technical Specificationsintelligent Optical Link Mapper 169FTB-7300EFTB-7300ETECHNICAL SPECIFICATIONSModelFTB-7300E aWavelength (nm) b1310 ± 20/1490 ±

Page 86

Technical Specifications170 iOLMFTB-7400EFTB-7400EAll specifications valid at 23 °C ± 2 °C with an FC/APC connector, unless otherwise specified. TECHN

Page 87

Technical Specificationsintelligent Optical Link Mapper 171MAX-715BMAX-715BTECHNICAL SPECIFICATIONS MAXTESTER 715BDisplay 7 in (178 mm) outdoor-enhanc

Page 88 - 3. Tap Import

Technical Specifications172 iOLMMAX-720BMAX-720BTECHNICAL SPECIFICATIONS MAXTESTER 720BDisplay 7 in (178 mm) outdoor-enhanced touchscreen, 800 x 480 T

Page 89

Technical Specificationsintelligent Optical Link Mapper 173MAX-730BMAX-730BTECHNICAL SPECIFICATIONS MAXTESTER 730BDisplay 7 in (178 mm) outdoor-enhanc

Page 92

Indexintelligent Optical Link Mapper 175IndexAadd element ... 125after-sales service ...

Page 93 - 7 Starting an Acquisition

Index176 iOLMimporting a test configuration ... 81iOLM wavelength(s) ... 43IOR ...

Page 94

Indexintelligent Optical Link Mapper 177splice... 116splitter ratio ...

Page 95 - 3. Tap Start

NOTICE抩⛙CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONT

Page 96

MARKING REQUIREMENTS㪖㽷尐㻑Productℶ❐Environmental protection use period (years)䘾⬒≬㔳∎䞷㦮棟 ( ㄃ )Logo㪖㉦This E;)2 product㦻 EXFO ℶ❐10Batterya䟄㻯aa. If applicabl

Page 97

www.EXFO.com · [email protected]/N: 1067569CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADATel.: 1 418 683-0211 · Fax: 1 418 683-

Page 98 - Stopping an Acquisition

intelligent Optical Link Mapper 132 Safety InformationWARNINGDo not install or terminate fibers while a light source is active. Never look directly in

Page 99 - 8 Understanding Diagnostics

ii iOLMCopyright © 2011–2015 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted

Page 100

Safety Information14 iOLMLaser Safety Information (Units Without a VFL)Laser Safety Information (Units Without a VFL)Your instrument is a Class 1M las

Page 101 - (Optional on Some Models)

Safety Informationintelligent Optical Link Mapper 15Laser Safety Information (Units Without a VFL)Laser information of the VFL. Always refer to the us

Page 102

Safety Information16 iOLMLaser Safety Information (Units With a VFL)Laser Safety Information (Units With a VFL)Your instrument is a Class 3R laser pro

Page 103

intelligent Optical Link Mapper 173 Getting Started with Your iOLMNote: Please refer to your platform's or unit’s user guide for detailed informa

Page 104 - Saving the Power Level

Getting Started with Your iOLM18 iOLMStatus BarStatus BarThe status bar, located at the bottom of the main window, identifies the selected configurati

Page 105 - View tab

intelligent Optical Link Mapper 194 Preparing your iOLM for a TestCleaning and Connecting Optical FibersTo connect the fiber-optic cable to the port:1

Page 106 - 100 iOLM

Preparing your iOLM for a Test20 iOLMCleaning and Connecting Optical Fibers3. Carefully align the connector and port to prevent the fiber end from tou

Page 107

Preparing your iOLM for a Testintelligent Optical Link Mapper 21Installing the EXFO Universal Interface (EUI)Installing the EXFO Universal Interface (

Page 109

intelligent Optical Link Mapper 235 Setting User PreferencesThe User Preferences window allows you to set general settings, identification settings, a

Page 110 - 104 iOLM

Contentsintelligent Optical Link Mapper iiiContentsCertification Information ...

Page 111

Setting User Preferences24 iOLMDefining General Settings2. Select the General tab.3. Under the General tab, configure the following settings: File Fu

Page 112

Setting User Preferencesintelligent Optical Link Mapper 25Defining General Settings Export OTDR Bellcore (.sor) file on save: If enabled, an OTDR Bel

Page 113

Setting User Preferences26 iOLMDefining Measurement IdentificationDefining Measurement IdentificationYou can define the measurement identification inf

Page 114 - Starting the OTDR Application

Setting User Preferencesintelligent Optical Link Mapper 27Defining Measurement Identification2. Select the Identification tab.3. Define the identifica

Page 115 - 12 Managing Results

Setting User Preferences28 iOLMCustomizing the File NameCustomizing the File NameThe application provides a way to define the name of the file to be s

Page 116 - Link Overview

Setting User Preferencesintelligent Optical Link Mapper 29Customizing the File Name2. Select the Filename tab.Standard measurementLoopback measurement

Page 117 - Link Composition

Setting User Preferences30 iOLMCustomizing the File Name3. Select which component you want to include in the file name from the list of available choi

Page 118

Setting User Preferencesintelligent Optical Link Mapper 31Customizing the File Name5. If you have the loopback (LB) software option, under Loopback pr

Page 119 - Link View

Setting User Preferences32 iOLMCustomizing the File Name6. Tap Apply to save the changes. 7. Tap OK to save the changes and close the window, or tap C

Page 120 - Link Groups

Setting User Preferencesintelligent Optical Link Mapper 33Naming iOLM Files AutomaticallyNaming iOLM Files AutomaticallyEach time you start an acquisi

Page 121

Contentsiv iOLM7 Starting an Acquisition ...87Starting an iOLM Acquisition

Page 122 - Link View Elements

Setting User Preferences34 iOLMNaming iOLM Files AutomaticallyConsider the figure below as an example of autonaming feature.You can find the above win

Page 123

Setting User Preferencesintelligent Optical Link Mapper 35Naming iOLM Files AutomaticallySelect two, three, or four "#" if you want all valu

Page 124 - Power Meter Results

Setting User Preferences36 iOLMNaming iOLM Files AutomaticallyAfter an acquisition is successfully saved, the file name is the combination of job ID,

Page 125 - Loopback Results

Setting User Preferencesintelligent Optical Link Mapper 37Customizing the iOLM ReportCustomizing the iOLM Report The application allows you to persona

Page 126 - Global Pass/Fail Status

Setting User Preferences38 iOLMCustomizing the iOLM Report3. If your unit allows it, select the report file type from File type option.4. Select the O

Page 127 - Loopback mode

Setting User Preferencesintelligent Optical Link Mapper 39Customizing the iOLM Report7. If you have the loopback (LB) software option, under Loopback,

Page 128 - 122 iOLM

Setting User Preferences40 iOLMCustomizing the Optical Power MeterCustomizing the Optical Power MeterThe OPM tab is available when an inline power met

Page 129

Setting User Preferencesintelligent Optical Link Mapper 41Customizing the Optical Power Meter2. Select the OPM tab.3. Select the power meter mode. The

Page 130

Setting User Preferences42 iOLMConfiguring your iOLMConfiguring your iOLMThe iOLM tab displays the settings used for taking measurements. The iOLM per

Page 131 - Adding Elements

Setting User Preferencesintelligent Optical Link Mapper 43Configuring your iOLMTo configure the iOLM:1. From the main window, select the iOLM tab.2. I

Page 132 - 126 iOLM

Contentsintelligent Optical Link Mapper v16 Warranty ...

Page 133

Setting User Preferences44 iOLMConfiguring your iOLM4. Specify if a launch and receive fibers are connected to the link under test, and enter their le

Page 134 - 128 iOLM

intelligent Optical Link Mapper 456 Managing Test ConfigurationsThis section explains the procedure to select, create, view and modify the test config

Page 135

Managing Test Configurations46 iOLMSelecting a Test ConfigurationTo select the test configuration:1. From the Main Menu, tap Test Config.2. Tap Select

Page 136 - 130 iOLM

Managing Test Configurationsintelligent Optical Link Mapper 47Selecting a Test Configuration3. Select the test configuration file.Note: If you have se

Page 137 - Deleting Elements

Managing Test Configurations48 iOLMImpacts of Test ConfigurationsImpacts of Test ConfigurationsBefore performing an acquisition, you can select or edi

Page 138 - Analyzing Links

Managing Test Configurationsintelligent Optical Link Mapper 49Creating a Test ConfigurationCreating a Test ConfigurationThe Duplicate button allows yo

Page 139

Managing Test Configurations50 iOLMCreating a Test Configuration2. Select Manage.3. Select the test configuration file to duplicate.4. Tap Duplicate.

Page 140 - Measurement Information

Managing Test Configurationsintelligent Optical Link Mapper 51Modifying a Test Configuration5. The default file name is displayed. You can modify the

Page 141

Managing Test Configurations52 iOLMModifying a Test ConfigurationModifying IdentifiersThe Identifiers tab allows you to view and modify the identifier

Page 142 - 136 iOLM

Managing Test Configurationsintelligent Optical Link Mapper 53Modifying a Test Configuration3. Select the test configuration file to modify. 4. Tap Mo

Page 143 - 13 Managing Files

Certification Informationvi iOLMCertification InformationNorth America Regulatory StatementThis unit was certified by an agency approved in both Canad

Page 144 - Opening iOLM Files

Managing Test Configurations54 iOLMModifying a Test Configuration6. Under Identifiers, select the identifiers from the list of available choices. Note

Page 145 - Saving iOLM Files

Managing Test Configurationsintelligent Optical Link Mapper 55Modifying a Test ConfigurationTo modify link definition:1. From the Main Menu, tap Test

Page 146 - 140 iOLM

Managing Test Configurations56 iOLMModifying a Test Configuration3. Select the test configuration file to modify. 4. Tap Modify.The name of the config

Page 147 - Managing Files

Managing Test Configurationsintelligent Optical Link Mapper 57Modifying a Test Configuration6. Select the split ratio of a splitter at a given stage.S

Page 148 - Exporting OTDR Bellcore Files

Managing Test Configurations58 iOLMModifying a Test Configuration7. Tap OK to save the changes and close the window, or tap Cancel to exit without sav

Page 149

Managing Test Configurationsintelligent Optical Link Mapper 59Modifying a Test ConfigurationEnabling 2:N Splitters (Optional, iOLM EXpert Mode Only)Th

Page 150 - 144 iOLM

Managing Test Configurations60 iOLMModifying a Test ConfigurationTo enable the 2:N splitter:1. From the Main Menu, tap Test Config > Manage.2. Sele

Page 151 - Generating a Report

Managing Test Configurationsintelligent Optical Link Mapper 61Modifying a Test Configuration4. Select the Link Definition tab from the test Configurat

Page 152 - 2. Tap Report

Managing Test Configurations62 iOLMModifying a Test ConfigurationThe element pass/fail status remains unknown in the following scenarios: If any elem

Page 153

Managing Test Configurationsintelligent Optical Link Mapper 63Modifying a Test ConfigurationManaging Custom Elements (Optional, iOLM EXpert Mode Only)

Page 154

intelligent Optical Link Mapper 11 Introducing the intelligent Optical Link MapperThe intelligent Optical Link Mapper (iOLM) is an optimized applicati

Page 155 - 14 Maintenance

Managing Test Configurations64 iOLMModifying a Test Configuration4. Tap Link Definition > Edit Custom Elements.5. Enter the custom element name und

Page 156 - Cleaning EUI Connectors

Managing Test Configurationsintelligent Optical Link Mapper 65Modifying a Test ConfigurationTo modify the custom element:1. From the Main Menu, select

Page 157 - IMPORTANT

Managing Test Configurations66 iOLMModifying a Test Configuration5. Select the custom element name under the Name column and modify it as needed.6. Se

Page 158 - Recalibrating the Unit

Managing Test Configurationsintelligent Optical Link Mapper 67Modifying a Test ConfigurationTo delete the custom element:1. From the Main Menu, select

Page 159 - Recycling and Disposal

Managing Test Configurations68 iOLMModifying a Test Configuration5. Tap the or icon (depending on the unit) beside the custom element which you wa

Page 160

Managing Test Configurationsintelligent Optical Link Mapper 69Modifying a Test ConfigurationModifying Link Pass/Fail ThresholdsThis tab allows you to

Page 161 - 15 Troubleshooting

Managing Test Configurations70 iOLMModifying a Test Configuration2. Select Manage.3. Select the test configuration file to modify. 4. Tap Modify.

Page 162 - 156 iOLM

Managing Test Configurationsintelligent Optical Link Mapper 71Modifying a Test Configuration5. Select the Link P/F Thresholds tab.6. Under Link P/F Th

Page 163 - From the Main Menu, tap

Managing Test Configurations72 iOLMModifying a Test Configuration7. Tap OK to save the changes and close the window, or tap Cancel to exit without sav

Page 164 - Transportation

Managing Test Configurationsintelligent Optical Link Mapper 73Modifying a Test Configuration2. Select Manage.3. Select the test configuration file to

Page 165 - 16 Warranty

Introducing the intelligent Optical Link Mapper2 iOLMOTDR port (singlemode)OTDR port (singlemode live and On-line power meter)Active LED(ON when laser

Page 166 - Liability

Managing Test Configurations74 iOLMModifying a Test Configuration5. Select the Element P/F Thresholds tab. The Threshold column displays the threshold

Page 167

Managing Test Configurationsintelligent Optical Link Mapper 75Modifying a Test Configuration6. Enable the Apply pass/fail option to access the paramet

Page 168 - Service and Repairs

Managing Test Configurations76 iOLMModifying a Test ConfigurationModifying Power Meter Pass/Fail ThresholdsThis tab allows you to modify the power met

Page 169

Managing Test Configurationsintelligent Optical Link Mapper 77Modifying a Test Configuration2. Select Manage.3. Select the test configuration file to

Page 170

Managing Test Configurations78 iOLMModifying a Test Configuration5. Select the OPM P/F Thresholds tab.6. Under OPM P/F Thresholds, modify the followin

Page 171 - A Technical Specifications

Managing Test Configurationsintelligent Optical Link Mapper 79Modifying a Test ConfigurationDeleting Test ConfigurationThe Delete button allows you to

Page 172 - FTB-720G

Managing Test Configurations80 iOLMModifying a Test Configuration2. Select Manage.3. Select the test configuration file to delete. 4. Tap Delete.A con

Page 173 - Technical Specifications

Managing Test Configurationsintelligent Optical Link Mapper 81Importing or Exporting a Test ConfigurationImporting or Exporting a Test ConfigurationTh

Page 174 - FTB-730G

Managing Test Configurations82 iOLMImporting or Exporting a Test Configuration2. Select Manage.3. Tap Import.

Page 175 - FTB-7300E

Managing Test Configurationsintelligent Optical Link Mapper 83Importing or Exporting a Test Configuration4. An Import dialog box opens, select the fil

Page 176 - FTB-7400E

Introducing the intelligent Optical Link Mapperintelligent Optical Link Mapper 3HandleVisual fault locator (VFL) port (optional)OTDR port (singlemode)

Page 177 - MAX-715B

Managing Test Configurations84 iOLMImporting or Exporting a Test ConfigurationTo export a test configuration:1. From the Main Menu, tap Test Config.2.

Page 178 - MAX-720B

Managing Test Configurationsintelligent Optical Link Mapper 85Importing or Exporting a Test Configuration3. Select the test configuration file. 4. Tap

Page 180

intelligent Optical Link Mapper 877 Starting an AcquisitionThis section explains the acquisition process of the iOLM.Starting an iOLM AcquisitionThis

Page 181

Starting an Acquisition88 iOLMStarting a Single-Wavelength AcquisitionStarting a Single-Wavelength AcquisitionThe single-wavelength acquisition allows

Page 182

Starting an Acquisitionintelligent Optical Link Mapper 89Starting a Single-Wavelength Acquisition2. Select the desired iOLM Wavelength(s) (one wavelen

Page 183

Starting an Acquisition90 iOLMStarting a Multiple-Wavelength AcquisitionStarting a Multiple-Wavelength AcquisitionThe multiple-wavelength acquisition

Page 184 - ₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩

Starting an Acquisitionintelligent Optical Link Mapper 91Starting a Multiple-Wavelength Acquisition2. Select the desired iOLM Wavelength(s).3. Tap Sta

Page 185 - MARKING REQUIREMENTS

Starting an Acquisition92 iOLMStopping an AcquisitionStopping an AcquisitionThe acquisition stops automatically after the acquisition is complete.It i

Page 186

intelligent Optical Link Mapper 938 Understanding DiagnosticsThis section explains the diagnostics feature available in the iOLM application. Diagnost

Commentaires sur ces manuels