Exfo IQS-3150 Variable Attenuator for IQS-500/600 Manuel d'utilisateur Page 137

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 161
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 136
SCPI Command Reference
Variable Attenuator 131
Product-Specific Commands—Description
:OUTPut[1..n]:POWer?
Description This query returns a value indicating either the
current or the minimum/maximum absolute
power value.
At *RST, the value that will be set is
device-dependent.
Syntax :OUTPut[1..n]:POWer?[<wsp>MAXimum|
MINimum|DEFault]
Parameter(s) Parameter 1:
The program data syntax for the first parameter is
defined as a <CHARACTER PROGRAM DATA>
element. The allowed <CHARACTER PROGRAM
DATA> elements for this parameter are:
MAXimum|MINimum|DEFault.
MINimum is used to retrieve the instrument's
lowest supported value.
MAXimum is used to retrieve the instrument's
highest supported value.
DEFault is used to retrieve the instrument's
default value.
Response Syntax <Power>
Vue de la page 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 160 161

Commentaires sur ces manuels

Pas de commentaire