Multimeter Tests
154 FTB-635
Capacitance/Opens Test
Setting Threshold Values
The Test Threshold page allows you to set the Threshold
Capacitance/Opens for each pair.
To set the Threshold values:
1. From the Copper main menu Test Groups, select Multimeter test
.
2. From the Tests menu, select Opens test.
3. Tap Snapshot or Continuous tab to set the Threshold values.
4. Tap Edit Thresholds button to open the Test Thresholds page.
5. Set the Threshold values as required.
6. Tap Close to confirm and exit the page.
The page allows you to set the following parameters:
Threshold is the threshold limit for each pair: Maximum, Minimum, or
None.
Threshold Capacitive Balance sets the threshold value.
Vue de la page 161