SCPI Command Reference
438 OTDR
Product-Specific Commands—Description
Response(s) Frequency:
The response data syntax for <Frequency> is
defined as a <NR3 NUMERIC RESPONSE DATA>
element.
The <Frequency> response corresponds to the
internal modulation frequency of the VFL, in Hz.
If the VFL is in CW mode, the returned value is 0.
Example(s) SOUR:VFL:AM:INT:FREQ 1
SOUR:VFL:AM:INT:FREQ? Returns 1
See Also SOURce[1..n]:VFLocator:AM:INTernal:FREQuenc
y
SOURce[1..n]:VFLocator:AM:STATe
SOURce[1..n]:VFLocator:POWer:STATe
SOURce[1..n]:VFLocator:POWer:STATe:TIME
:SOURce[1..n]:VFLocator:AM:INTernal:
FREQuency?