Exfo FTB-800 Series for FTB-1 Manuel d'utilisateur Page 41

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 621
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 40
Graphical User Interface Overview
NetBlazer 31
Global Indicator
Global Alarm
Indicates the current and history alarm/error status of the test.
Test Timer
The test timer without the timer icon indicates the time elapsed since the
beginning of the test. No timer action is active. The test timer format is “day
hour:minute:second”.
Timer
The timer icon with Armed indicates that a start time is active.
The timer icon with the Test Timer indicates that a duration and/or a stop
time is active.
Background
color
Alarm/
Error
Text
displayed
Description
Gray Current -- No test result available.
History
Green Current No Alarm No alarm/error has occurred in the
last second.
History No alarm/error has occurred during
the test.
Red Current Alarms or
the name of
the alarm.
An alarm/error occurred in the last
second.
History
Amber History No current alarm/error but at least
one alarm/error has occurred during
the test.
Vue de la page 40