Getting Started with Fault Isolation Tools
Copper, VDSL2, ADSL2+ and IP Triple-Play Test Set 15
Regional Settings
Regional Settings
Before executing fault isolation tools, set up the software settings and
values for the cables. The AXS-200/635i allows you to save standard
parameter settings to different profiles and reuse them as needed.
To access Regional Settings:
From the Home pane, select Fault Isolation Tools, then Regional
Settings.
The following parameters are available to configure:
Select Profile
The Select Profile tab allows you to
configure the unit with specific
measurement values.
Each parameter is described below:
³ Distance Units are the units of
measurement for distances in
FEET or METER.
³ Cable Gauge is the gauge system
for measuring wire sizes in AWG (American Wire Gauge) units or mm
(metric wire size).
³ Profile Name is either Default or a list of all available profile file names
stored in the current directory.
³ Clone Profile allows you to copy an existing profile to a new one and
switch to use the new profile.
To select the parameter values:
1. Press the up/down arrow keys to highlight the desired parameter.
2. Press to display the list.
3. Use the up/down arrow keys to highlight the desired value, and press
to accept the value.