Summary Tabs
Ethernet and Fibre Channel Application 123
Test Summary
SAM Test Status: Indicates the EtherSAM test status message.
Test Status Desciption
Pending (--) No sub test is started.
Running... A sub test is currently running.
Data Transfer... A sub test is running but no test traffic is
being transmitted.
Completed, <Verdict> A sub test has completed. <Verdict>
represents the test global verdict upon
completion of the sub test.
Aborted, <Reason> A sub test has been aborted either manually
(Stop) or by an alarm. <Reason> represents
the reason why the test has been aborted.
Possible reasons are:
Link down alarm
LOS alarm
DTS connection failed
Timeout during execution (DTS)
Unresolved addresses
No test enabled
Stopped.